Installer Mode Programming i-on40
Page 46
menu but does not give any exit tones.
When the system sets the keypad gives
a double beep confirmation tone.
The keypad(s) give a double beep
confirmation tone at the end of all
setting modes.
Settle Time
This option allows you to define a time delay to allow
detectors to settle before the system sets. This may
be needed if detectors are being set off by air
movements caused by the final door being closed.
During this period, the sounders stop and the system
sets but the control unit ignores any alarms
generated by the detectors.
Enter two digits to specify a time in seconds, from 01
to 30.
Note: This option is available for Final Door Set exit mode
only.
Exit Time
The exit time can take any value between 10s and
120s.
Note: If you select Final Door Set or Instant Set for the
exit mode then the Exit Time option does not appear
in the menu.
Entry Time
The entry time can take any value between 10s and
120s. The entry time you select in this option applies
to Full set and all Part Sets.
Strobe on Set (Part Set Strobe Set)
When set to ON this option causes the control unit to
activate any output programmed as Strobe, plus the
strobe on any 760ES wireless siren. The
outputs/strobes are active for three seconds after the
system sets. Strobe On Set applies to Full Set and all
the Part Sets.
Strobe on Unset (Part Set Strobe on Set)
When set to ON this option causes the control unit to