i-on40 Installer Mode Programming
Page 11
2. When you have found the zone you wish to edit press
> or Y.
The bottom line of the display shows “Name”.
3. Press u or n to see the Type, Attributes or Partition
options for that zone. Press
> or Y to select the
option you wish to change.
Note: If you selected “Part set mode” during Initial
Power-up then the display will not show the
Partitions option (see System Options–Restore Defaults–
Factory Defaults on page 53 if you want to change the
system from Part Setting to Partitions).
If a zone has the type “Not Used” then the Attributes
and Partition options do not appear.
4. Press Y to confirm and store any changes.
Changing Zone Names
For hints on editing zone names see page 7.
Zone Types
When the control unit first learns a detector the zone type
defaults to Normal Alarm. The bottom line of the display
shows a “*” at the beginning to show the zone’s current
type.
(Hint: You can select a zone type quickly by keying the
number shown in brackets after the type’s name, for
example:“05” to select Final Exit, “02” to select Fire
Alarm, “11” to select External PSU A/C Fail. The number
does not appear on the keypad display.)
The zone types available are:
Not Used (00)
The alarm system will not respond when an event
triggers this detector.
Panic Alarm (01).
Operating a device programmed as ‘Panic Alarm’ (PA)
will start an audible alarm. If a communications
module is fitted there may also be an alarm
transmission to the Alarm Receiving Centre (ARC),
depending on how you have programmed the ARC