i-on40
Page 23
Monitoring
includes
Mains fail, battery low
voltage, battery failure.
Electromagnetic
Compatibility
Immunity Conforms to EN50130-4.
Emissions Conforms to EN61000-6-3.
Outputs
O/P 1 - 2 Voltage free, single pole
relay contacts rated 24VDC
@ 1A.
O/P 3 - 4 Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
O/P 5 - 16 Open collector transistor
+12VDC when inactive, 0V
when active, 50mA max.
LS
(loudspeaker)
Min impedance 16 Ohm,
current consumption from
12VAux = 280mA in alarm.
Fuses
The control unit has a replaceable T250mA
mains fuse.
Electrical Safety
Conforms to EN60950-1.
Compliance Statements
This product is suitable for use in systems
designed to comply with PD 6662: 2004 at
grade 2 and environmental class II.
This product complies with the
requirements of EN50131-3 at grade 2 and
environmental class II.
This product complies with the
requirements of EN50131-6:2008 at grade
2 and environmental class II.
When fitted with an i-sd02 this equipment
is compliant with EN 50136-1. It allows the
alarm transmission system to meet the
performance requirements of EN 50131-
1:2006 ATS 2 provided that:
a) It is installed in accordance with the
installation instructions.
b) The connected PSTN is functioning
normally.
If the installer selects a non-
compliant configuration then they must
remove or adjust compliance labelling