11980075 Page 26
Appendix. Log Messages
Message Meaning
AC Fail Mains power supply failed
AC Restore Mains power supply restored
Al Conf Dis K== Alarm confirmation disabled by
lock switch
Al Confirm Z== Confirmed alarm on zone ==
Alarm Abort User aborted alarm
AntiMask Al Z== Anti-mask alarm on zone ==
AntiMask Rs
Z==
Anti-mask alarm on zone ==
reset
AntiMask Tp Z== Tamper on anti-mask zone ==
AUX DC Fail Auxiliary power failed
AUX DC Fail
Rstr
Auxiliary power restored
Bad Checksum Control unit memory corrupted
Batt Flt Rstr Battery reconnected
Batt Load Fail Battery failed load test
Batt Missing Battery disconnected
Bell Tamper Sounder tampered with
Bell Tamper Rst Sounder tamper reset
Burg Z== Alarm Intruder alarm on zone ==
Burg Z== Rstr Intruder alarm on zone ==
reset
Codes Defaulted Access codes returned to
default values
Comms Fail Communications failure
Defaults Loaded Default values loaded for all
commands
EEPROM Fail Control unit memory damaged
F== Missing Forbikobler keypad
disconnected
F== Restore Forbikobler keypad
reconnected
F== Tamper Forbikobler keypad tampered
with
Fire Reset Fire alarm reset
Fire Z== Alarm Fire alarm on zone ==
Fire Z== Rstr Fire alarm on zone == restore
Forbi I/F Tamper Forbikobler interface tampered
with
Forbi Lp Tamper Forbikobler loop tampered with
Fr K== Alarm Fire alarm started at keypad
==
Message Meaning
Frb I/F Tamp Rst Forbikobler interface tamper
reset
Frb Lp Tamp Rst Forbikobler loop tamper reset
Global T.Restore Global zone tamper alarm
reset
Global Tamper Global zone tamper alarm
K== Excess
Keys
Incorrect access code entered
more than four times at keypad
==
K== Missing Keypad == disconnected
K== Restore Keypad == reconnected
K== Tamper Keypad == tampered with
Key Box Cls Z== Keybox on zone == closed
Key Box Opn
Z==
Keybox on zone == open
Key Sw Set # System set by keyswitch on
level n
KeySw Unset # System unset by keyswitch on
level n
Lid Tamp
Restore
Control unit lid tamper reset
Lid Tamper Control unit lid tampered with
Low Batt Rstr Low battery detected on
control unit
Low Batt Rstr
Z==
Low battery reset on control
unit
Md K== Alarm Medical alarm started at
keypad ==
PA K== Alarm Panic alarm started at keypad
==
PA Z== Alarm Panic alarm started in zone ==
PA Z== Rstr Panic alarm reset in zone ==
Set Fail Z== System failed to set because
of fault in zone ==
Smk Det Alm
Z==
Smoke detector alarm in zone
==
Smk Det Res
Z==
Smoke detector alarm reset
zone ==
Soak Fail Z== Soak test failed in zone ==
System
Rearmed
System rearmed after an alarm
System Startup Power applied to system