3. Installation
Comms O/P1 (Brown) -ve applied (+ve removed) in alarm
Comms O/P2 (Orange) -ve applied (+ve removed) in alarm
Comms O/P3 (Yellow) -ve applied (+ve removed) in alarm
Comms O/P4 (Green) -ve applied (+ve removed) in alarm
Comms O/P5 (Blue) -ve applied (+ve removed) in alarm
Comms O/P6 (Purple) -ve applied (+ve removed) in alarm
Comms O/P7 (White) -ve applied (+ve removed) in alarm
Comms O/P8 (Grey) -ve applied (+ve removed) in alarm
Line Fail input (White/Brown) +12V applied to indicate telephone line fail
Tell Back input (White/Orange) +12V applied to change from engineer to customer reset
0V (Black)
12V (Red)
Com Connector Cable, Part No. 485210
Figure 20. Communications Wiring Harness.
4. Plug the Communications Wiring Harness onto the communications
connector on the main PCB (see Figure 3 or 4).
6. If using the Junior Combi box then re-fit the PCB to the support pillars.
Secure the PCB to the support pillars with the screws provided (Figure
21). Make sure that the bottom left corner of the PCB is seated on its
support pillar.
Figure 21. Fitting Control Unit PCB