Engineering Manual Engineer Menu 2-5
113
Log Message/Event
SIA
CODE
CID
CODE Basic Summary Intermediate Full
ALARM #### BA 130 Y Y Y Y
ATE L.F. ALL LT 351 Y Y Y Y
ATE L.F. RESTORE LR 351 Y Y Y Y
ATE L.F. SINGLE LT 351 Y Y Y Y
AUTOSET 1 OFF OP 401 Y Y
AUTOSET 1 ON CL 401 Y Y
AUTOSET 2 OFF OP 401 Y Y
AUTOSET 2 ON CL 401 Y Y
AUTOSET 3 OFF OP 401 Y Y
AUTOSET 3 ON CL 401 Y Y
AUX RESTORE #### YQ Y Y Y
AUXILIARY #### UA 150 Y Y Y Y
Auxiliary 1 Tamp TA 137 Y Y Y Y
Auxiliary 2 Tamp TA 137 Y Y Y Y
AUXILIARY FUSE YP Y Y Y
Battery Fault YT 311 Y Y Y
BELL FUSE TA 137 Y Y Y Y
BELL TAMP OMIT BB 573 Y Y Y Y
CHANGE CODE ## JV 461 Y
CHANGE TAG ## JV 461 Y
CODE TAMPER JA 461 Y
COMMS FAILED YC 350
COMMS TEST CALL RP 602 Y Y Y Y
DATE CHANGED AT JT 625 Y
DATE CHANGED TO JT 625 Y
DEFAULT USER JX Y
DEFAULT USER ## JV 461 Y
DEFERRED SET:- CE Y
DL DISCONNECT FL RU 412 Y
DL DISCONNECT OK RS 412 Y
DURESS CODE ## HA 121 Y Y Y Y
ENG HW DEFAULTED JV 461 Y
ENGINEER ARRIVES LB 627 Y
ENGINEER DEPARTS LS 628 Y
ENTRY TIME-OUT:- BA 130 Y Y Y Y
EXT LINE FAULT LT 351 Y Y Y Y
EXT LINE RESTORE LR 351 Y Y Y Y
FAULT 4K4 #### IA 389 Y Y Y
FIRE ALARM #### FA 110 Y Y Y Y
FIRE RESET. #### FR 110 Y Y Y Y
HI-SECURITY SET: CL 401 Y Y
ID LOOP RESTORED TR 137 Y Y Y Y
ID LOOP SHORTED TA 137 Y Y Y Y
KEYPAD PANIC ### PA 123 Y Y Y Y
LOCAL ON LINE RB 412 Y
LOCKSET #### ON CL 409 Y Y
LOCKSET #### OFF OP 409 Y Y
LOCKSET WARD ON CL 409 Y Y