7510r
Page 15
Programming
Entering Installer Menu
1. Make sure the system is unset and showing the
standby screen (time and date).
2. Press Menu.
3. Key in your Installer access code.
(When delivered from the factory the default Installer
access code is “7890”).
When you key in the last digit of the access code the
keypad displays the first item on the Installer Menu.
4. Press u or n to display more items from the menu.
5. Press SELECT to enter that item of the menu.
Leaving the Installer Menu
1. Press DONE or BACK until the top line of the display
shows the words “Installer Menu”.
2. Press EXIT to leave Installer Menu.
The display shows “Leave Installer Mode?”.
3. Press YES.
The display shows the time and date. The system is
ready for use.
Restoring the Access Codes (1
st
stage Reset)
If the user and/or Installer codes are lost then:
1. First remove mains power, then open the case and
disconnect the battery (see Figure 4).
2. Identify the Reset pins on the main PCB (see Figure
4).
3. Short the Reset pins together using a small wire link.
4. Reconnect the battery.
Note: If you need to run the control unit from the battery
temporarily, then briefly short the Kickstart pins
together. The control unit will not operate from a
battery unless you do this.